Engine speed

Last reviewed 2026-08-31

Mode 01 · PID 0C (decimal 12)

Description

Crankshaft speed. The most widely implemented Mode 01 PID. On a hybrid this is the ICE, not MG1/MG2.

PID number
0C · 12
Unit
rpm
Range
0 … 16383.75
Data bytes
2
Formula
((A*256)+B)/4

Defined by SAE J1979 / ISO 15031-5. Public index — not a substitute for the paid SAE document.